Home Standby Generators |
| 7, 12 & 15 kW SPECIFICATIONS
(back) |

- Quiet, powerful OHVI single-cylinder or V-Twin engines
fueled by natural gas or LP gas.
- UL Listed remote-mounted pre-wired automatic transfer switch
with 8, 10 or 12 circuit emergency load center for fast and efficient
unattended transfer to generator when utility power fails.
- A standard weather protective enclosure with sound-absorbing
panels protects generator from harmful weather and also reduces
exterior noise levels. Includes key locks for security.
- Hinged top and removable front panel for easy serviceability.
- Built-in charger maintains battery at optimum performance level.
- Automatic safety shutdowns protect engine and generator in
event of low oil pressure, high temperature, overspeed and/or
overcrank.
- Automatic seven-day exerciser runs the system for twelve minutes
weekly to maintain top running condition.
|
|
GENERATOR SET |
|
|
|
| Model
Number |
04389 |
04456 |
04390 |
| Rated
Power LP (kW) |
7 |
12 |
15** |
| Rated Power
NG (kW) |
6 |
12 |
13 |
| Voltage
@ 60 Hz |
120/240 |
120/240 |
120/240 |
| Phase |
Single |
Single |
Single |
| Frequency |
60
Hz |
60
Hz |
60
Hz |
| Amps LP |
58.3/29.2 |
100.0/50.0 |
125.0/62.5 |
| Amps
NG |
50.0/25.0 |
100.0/50.0 |
108.3/54.2 |
| Engine/Alternator
RPM |
3600/3600 |
3600/3600 |
3600/3600 |
| Engine |
410
cc.
14.5 HP
Generac OHVI
Single Cylinder |
992
cc.
30 HP
Generac OHVI
V-Twin |
992
cc.
30 HP
Generac OHVI
V-Twin |
| EPA/CARB Certified |
Yes |
Yes |
Yes |
| Fuel |
Natural
Gas/
LP Vapor |
Natural
Gas/
LP Vapor |
Natural
Gas/
LP Vapor |
| Engine Cooling |
Air |
Air |
Air |
| UL2200 |
Yes |
Yes |
Yes |
| CSA Listed |
Yes |
Yes |
Yes |
| Main
Line Circuit Breaker |
40
Amp |
50
Amp |
60
Amp |
| Dimensions
(L" x W" x H") |
48 x 24 x
28-1/4 |
48 x 24 x
28-1/4 |
48 x 24 x
28-1/4 |
| Unit
Wt. (lbs.) |
452 |
470 |
487 |
|
CONTROLS |
|
| Start/Stop
Control |
Cyclic
cranking: 7 seconds on, 7 seconds rest. 90 seconds overcrank protection. |
| Automatic
Low Oil Shutdown |
Standard |
| Overspeed
Shutdown |
Standard,
72 Hz |
| Overcrank
Protection |
Standard |
| Automatic
Voltage Regulator with Over-Voltage Protection |
Standard |
| Engine
Warmup |
10
seconds |
| Engine Cool-Down |
1 minute |
| Safety
Fuse |
Standard |
| Starter
Lockout |
Starter
cannot re-engage until 5 seconds after the engine has stopped |
| 2
Amp Timed Trickle Battery Charger |
Standard |
| Auto Switch |
Utility
failure/7 day exercise |
| Off
Switch |
Stops
unit. Power is removed. Control and charger still operate |
| Manual
/ test |
Start
with starter control, unit stays on. If utility fails,transfer to
load takes place |
|
TRANSFER
SWITCH |
|
| No. of Poles |
2 |
| Current
Rating (amps) |
100 |
| Voltage
Rating (VAC) |
250 |
Utility
Voltage Monitor (fixed)
Pick-up
Drop out |
80%
60% |
| Return to
Utility |
Approx.
13 seconds |
| Exercises
7 minutes weekly |
Standard |
| UL Listed |
Standard |
| Dimensions
(H" x W" x D") |
26.5